Page 26
11/12/24
8. Vinegar Titration Lab
Purpose:
Determine the concentration of acetic acid in vinegar.
Procedure:
-
- Using a clean funnel, fill a buret with NaOH solution, which was determined to have a molarity of 1.00M. Record the initial volume of NaOH in the buret.
- Measure out 10mL of vinegar using a graduated cylinder. Transfer the vinegar into an Erlenmeyer flask. Add 2 drops of phenolphthalein to the flask.
- Slowly add the 1.00M NaOH to the vinegar in 1-2mL increments. As the endpoint
nears.nears, the color change of the indicator slows. If you feel that you need less than a drop of NaOH, wash the tip of the buret and walls of the fask was a very small amount of distilled water. Continue to add NaOH until the endpoint is reached. The endpoint should be a very paint pink color. Record the final volume of NaOH in the buret. - Refill the buret if necessary and repeat the titration process at least 2 more times.
- Calculate the molarity of the NaOH solutions for each trial.
- Calculate the percent deviation between the trials. (high-low)/avg*100)
- If the % deviation is greater than 2%, repeat the titration process.